The status of each job step may be tested at the end of each job step. The following PROCEDURE DIVISION statement shows how to convert from a PACKED to a DISPLAY (with SIGN TRAILING SEPARATE) numeric value. The fewer decimal positions of the result field will cause the numeric value to be truncated. Category and Balance. This test case will show the process for converting a binary numeric format to an edited numeric format. Save my name, email, and website in this browser for the next time I comment. Dictionary debit type category debit value debit, to debit, to debit-side settlement debit/credit amount debited interest debiting and crediting an account debits debits and credits debits/credits indicator debt discount debt instrument debt instrument debt register debt to total capital debt-equity ratio debtor debug debugging debugging . The light-blue boxes identify the input/output data structures such as Documents, Spreadsheets, Data Files, VSAM Data Sets, Partitioned Data Set Members (PDSM's) or Relational Tables. NULL value, which is used as the string terminator. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies. This assumes the string value is made up of 3 parts separated by spaces. The only method to get this done is to use a File Master Reformat data set, aka. . For eg., i have alphanumeric string converting string to pack decimal form - IBM Cobol - IBM Mainframe Forum This section provides various test cases for converting different types of numeric fields. It is comp of some kind. Color Associations: The light-green boxes are unique to SIMOTIME Technologies using an IBM Mainframe System or Micro Focus Enterprise Developer. This test case will show the process for converting a packed-numeric format to an edited numeric format. The discussions include further detail about the issues and concerns of unsigned (or implied positive) numbers, signed (positive or negative) numbers and decimal or whole numbers. The following (NBRCVTE1.cmd) is a sample of the Windows CMD needed to run this job in a non-Mainframe environment. What you probably need to do is something along the lines of: Yes, the above program uses an additional variable in the middle to convert numeric format to display format, but that is exactly how the language was designed. The session will describe three of the popular numeric formats used with COBOL and IBM Mainframe systems. COBOL Computational Fields: comp, comp-3, packed decimal, binary - A and view the COBOL source code for this numeric field conversion example. What about WS-NUM-STR consisting of a dummy field of pic x(9) and the value field of pic 9.999? We have to add four columns This test case will show the process for converting a zoned-decimal-numeric format to a display (or zoned-decimal) format. In my previous tip, I introduced aspects to consider when importing data from The low-order byte contains one digit in the leftmost portion and the sign (positive or negative) in the rightmost portion. Is there an existing gem or script that converts comp-3/packed decimal format to number? Why do many companies reject expired SSL certificates as bugs in bug bounties? Refer to The lower nibble of the last byte has 13 if the number is negative, and something else, (usually 12) if positive. 04 COBOL: Zoned Decimal and packed decimal - YouTube S9(15) means a 15 digit numeric signed field: S for sign, 9 is numeric, (15) is length. On the other hand, you can use the NumVal (or NumVal-C) intrinsic functions (with any compiler supporting the '89 ANSI/ISO amendment) to the "numeric" values of an alphnanumeric field that contains spaces, decimal points, comma, (or with NumVal-C) currency signs. Parent topic: Reformatting records with fixed fields. To convert from zoned to packed. convert 1 BYTE binary to decimal in cobol - IBM Cobol - IBM Mainframe Forum And Please suggest any other way to achieve the same! The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. In my use case I had to use suggestion from both of your posts. one digit per byte. we need to select DT_BYTES as the Data Type; and 1 and 6 for its lengths Since packed decimal data you can't read in the EDIT field, you can specify a format you want for display. To subscribe to this RSS feed, copy and paste this URL into your RSS reader. 80, Jubilee Hills, Hyderabad-500033 router bridge mode explained + 91 40 2363 6000 how to change kindle book cover info@vspl.in Where developers & technologists share private knowledge with coworkers, Reach developers & technologists worldwide, Interpreting COMP-3 Packed Decimal Fields into numeric values, http://jrecord.cvs.sourceforge.net/viewvc/jrecord/jrecord/src/net/sf/JRecord/Common/Conversion.java?revision=1.2&view=markup, How Intuit democratizes AI development across teams through reusability. A suite of Bash Script Files is provided to run the jobs on a Linux or UNIX System with GnuCOBOL (formerly known as Open COBOL) being used to compile and execute the COBOL Programs. The following PROCEDURE DIVISION statement shows how to convert from a PACKED to a EDITED numeric value. To change this to readable format, you need to convert these numbers into ZONED Decimal (ZD) format. please suggest a method to convert a numeric field to packed decimal in cobol program. Packed-Decimal Format, Description and Discussion - SimoTime the record definition) for the file of the previous step. Copyright 1987-2023SimoTime Technologies and ServicesAll Rights Reserved. for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This file used to be written by a COBOL program and this one field was written using COMP-3. If it is not, there will be an 0c7. How do you convert a packable decimal to a readable format? A suitable definition for a table to load this file is next. COMP-3 in COBOL - GeeksforGeeks a SELECT to the destination table and you will see that 1000 rows have been loaded Raja, If done correctly, as Gilbert's is, I don't see how you'll S0C7. The next is close to what you will see in a COBOLs Copy File (a file that contains Get alphanumeric string redefined into two numeric fields to hold and process decimal part and integer part individually. The next step is to set up the Inputs and Outputs tab. You can't define your field decimals like that and use it in a COMPUTE. and view the COBOL source code for this numeric field conversion example. P stands for Packed - in Easytrieve variable declaration. Just use the assignment statement using "=" (equal) symbol. For example, the value 15 is stored in two nibbles, using the hexadecimal characters 1 and 5. Integration Services Data Flow Transformations, SQL Server Integration Services Data Type Conversion Testing, Integration Services Data Flow Transformations Tips Category, SQL Server For example, I have a 2 character field with value of PR. Informats: Working with Packed Decimal and Zoned Decimal Data - 9.2 - SAS This numeric structure is supported by COBOL and may be used with an edit-mask to prepare the presentation for readability by human beings. You need to programmatically account for it. Software Agreement and Disclaimer. Redefine the 2-byte alphanumeric variable as PIC S9 (04) COMP. That is a File Master 3.11 Reformat example: ------------------ CA File Master Plus -- Dataset Reformat ------------------. Better idea please explain what you are trying to do. Beginning with version 4.1.1 of COBOL for AIX, during the conversion of a numeric data item to and from a packed-decimal data item, negative zero is no longer converted to positive zero. Using V6.2 and ARCH(12), the compiler instead uses the vector packed-decimal facility, which accelerates packed and zoned decimal computation by storing intermediate results in vector registers instead . if itab-menge has a value of 2.00, i need to convert that value to ' 200'. previous tip, SSIS offers us the possibility to extend its functionality by Packed Decimal Data. 9(3) is a three digit numeric, and COMP-3 is BCD encoded decimal. The following (NBRCVTJ1.jcl) is a sample of the ZOS oriented JCL needed to run this job in a Mainframe-oriented environment. Negative zero behaves the same as positive zero computationally. image will clarify things. Difference between "select-editor" and "update-alternatives --config editor". 1) Simply using the move statement in the cobol prog. This first patch isn't directly applicable to all the projects, but if this is approved then I have follow-on patches for gdb and binutils. The Source Field is defined as a Zoned-Decimal (or USAGE IS DISPLAY) and the result fields are "USAGE IS DISPLAY" or a numeric edited field. Wikizero - Binary-coded decimal So the comp-3 field of size 4 bytes can store an numeric digits of +999,9999 to -999,9999 digits. For detailed information on DFSORT's numeric conversion parameters, see z/OS DFSORT Application Programming Guide. Hope you could figure out. Coming to redefining with value field of PIC 9.999 doesnt work because 9.999 is a picture edited type, which will be useful for displaying/output purpose and will still not be able to do the required arithmetic. One copybook for the source data structure and one for the new data structure.For example: 01 DATAREC1OLD. The Floating-Point format should wait until another time after you well understand these four. I tried to import 40000 rows using the next format : 02 SUC-OUT PIC X(3). The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources. The Source Field is defined as a Zoned Decimal field with 6 digits and 3 decimal positions. 02 FEC-AA PIC X(2). . take a look at. Suppose we have the number 40.06. 03 AMOUNT PIC S9(11)V99 COMP-3. This template defines Using Kolmogorov complexity to measure difficulty of problems? After I import the binary file, and choose DT_STR as data type and add the field to the VB script, the output looks just like the weird binary characters in the file. On the next image you can see a Now, on the Script Tab, press the Edit Script button. Why is this sentence from The Great Gatsby grammatical? Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? For example to store an numeric field of value 987 we would required 3 +1 divided by 2 = 2 Hence an Comp-3 field of length 2 bytes can store a value of +999 to -999 as the limit. the three parts of the Performance Exam will make-up 50% of the course's overall score. Joe, it is WS-EDITED-NUMBER from the REDEFINES which is being MOVEd, so no spaces. On the Advanced view we are going to add four columns named Name, Address, Making statements based on opinion; back them up with references or personal experience. Each byte has two nibbles, and each nibble is indicated by a hexadecimal character. Importing Mainframe Data including Packed Numbers with SSIS The problem with moving it to a numeric field is that ABCDEF are actually valid zoned-decimal digits. I know two methods for doing that. 1. For more information about the Hex-Dump format refer to the Hexadecimal Dump Format section of this document. JCL Procedure: Instream, Catalogue, Nested. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact, Comment or Feedback section of this document. copybooks. Thats it! Length specified in Easytrieve always specifies the number of bytes occupied and not number of digits. Note:A SimoTime License is required for the items to be made available on a local system or server. What is the purpose of this D-shaped ring at the base of the tongue on my hiking boots? 02 OPERADOR-OUT PIC X. How to use Slater Type Orbitals as a basis functions in matrix method correctly? Off: Plot No. This example also illustrates how to display the actual hexadecimal (or Hex Dump) content of a numeric field using a callable dump routine. On the Script Tab select Visual Basic as the Script Language. Although it only requests 18 digits (15+3), it gets 19 to make it an even length field with the sign (one digit added to the front to make it 10 bytes long on the file). download a sample text file. We have made a significant effort to ensure the documents and software technologies are correct and accurate. Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the icon. and view the COBOL source code for this numeric field conversion example. Book Description This book is intended to support ISPF application programmers to become professional in the smart programming of ISPF . Why does my COBOL working storage variable have trailing zeroes? The following PROCEDURE DIVISION statement shows how to convert from a ZONED-DECIMAL to an EDITED numeric value. It is so important that ** The last letter denotes the sign, C & F are positive, D is negative. 01 WS-ZONED-DECIMAL PIC S9 (11)V99. For the Nozomi from Shinagawa to Osaka, say on a Saturday afternoon, would tickets/seats typically be available - or would you need to book? The above internal table itab is passed to the Function module GUI_DOWNLOAD and the itab data is downloaded to a text file. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. digits. That is a File Master 3.11 Reformat example:------------------ CA File Master Plus -- Dataset Reformat ------------------OPTION ===> BLANK - Update Reformat Control Parms E - Execute Reformat Reformat "FROM": Dataset name ===> 'your.CONVERT.INPUT' Member name ===> Layout DSN ===> 'your.CONVERT.LIB' Layout member ===> CPYBK#O1 Reformat "TO": Dataset name ===> 'your.CONVERT.OUTPUT' Member name ===> Layout DSN ===> 'your.CONVERT.LIB' Layout member ===> CPYBK#N1 Replace Keys ===> N ('Y' to replace duplicate keys in KSDS) Reformat Control Parm: Dataset name ===> 'your.CONVERT.LIB' Member name ===> REFORMAT Execution mode ===> E O = Online S = Submit JCL E = Edit JCL After pressing enter you have to assign the "FROM" fields to the "TO" fields.